We now execute the validations when "kill" is executed even if match
criteria are used. This prevents users from killing workspace containers,
which instead kills all clients (as before when not using criteria).
fixes#1761
It should be clear for callers of this function that this is an internal
function that skips certain validations which might be important. Therefore
we make it clear that this is an internal function by renaming it.
relates to #1761
Previously, if a match specification contained the con_id or con_mark criterion,
all other criteria were ignored. However, a user may want to specify one of
those two unique identifiers and still specify others as well, for example to
match the currently focused window, but only if it has a certain WM_CLASS:
[con_id=__focused__ class=special] kill
We now check all specified criteria.
fixes#2111
Previously, using a command like
[con_id=foo] kill
would kill the currently focused window because while an error for
not being able to parse the con_id was logged, no further action
was taken, which caused the criterion to be ignored. In this case,
the fallback behavior of using the focused window took over.
For con_id, id and window_type we now reject incorrect values with
an error and abort the command.
fixes#2091
This patch extends the previously introduced flag --no-auto-back-and-forth
to also apply to
move window to workspace <name>
move window to workspace number <number>
relates to #2028
Since splitting a docking container was allowed and successful, the check
to prevent floating it fails to work. This causes a crash because the
workspace of the container cannot be determined as the dockarea is higher
up in the tree than the workspace it belongs to.
This patch extends to sanity check to nested dock containers when trying to
float a container and also disallows manually splitting a docked container
or changing its layout.
fixes#2034
Suppose a horizontally oriented workspace has two windows open. Issuing "split h" on
the right window creates a nested horizontal container. If we now resize in "width"
direction, the resize doesn't work because it will only operate on the current parent,
which is a container with only one child, so the resize command exits.
This is unexpected behavior from a user point of view. Hence, with this patch, we
ensure that we don't just go up the tree until we find a parent with the correct
orientation, but also keep going if that parent has only a single child.
fixes#2015
This patch introduces the --no-auto-back-and-forth flag to both of
workspace --no-auto-back-and-forth <name>
workspace --no-auto-back-and-forth number <number>
This flag will only have an effect if the back_and_forth feature is
enabled. If passed, the feature will be ignored for this particular
call only.
fixes#2028
This patch allows using 'unmark' on matched windows. The old behavior
of applying it to all windows if no criteria were specified is kept.
relates to #2014
In order to keep compatibility to before allowing multiple marks on a window,
we introduce a flag "--add" that must be set to put more than one mark on a
window. The default, which is also available as "--replace", keeps the old
behavior of overwriting a mark when setting a new one.
fixes#2014
This patch allows multiple marks to be set on a single window. The restriction that a mark may
only be on one window at a time is still upheld as this is necessary for commands like
"move window to mark" to make sense.
relates to #2014
This commit also reworks the way focusing sticky windows is prevented by not focusing them temporarily at all, but preventing the focus in the first place.
If the match expression is a plain number (e.g., '99'), the number of a workspace will be compared strictly. Otherwise, the match expression is taken as a regular expression and compared against the workspace's name.
This allows all of the following:
for_window [workspace=5] ...
for_window [workspace="5:foo"] ...
for_window [workspace="foo"] ...
fixes#1769
The format string set with "title_format" can contain the placeholder "%title" which will be replaced with the actual window title.
By not overwriting window->name itself, we make sure that assignment matching still works as expected.
fixes#1723
Try to detect base 16 numbers given to `con_id` and `id` for command criteria
by setting the base of strtol to 0. This should also detect octal.
This is necessary because mouse bindings now may be serialized as hex as of
5c32de4.
We only support unique marks, so looping over all matched windows must be prevented.
If more than one window is matched, we reject it with an error message.
fixes#1614